Ground Controls
2-6

Level Sensors

The Electronic Control Module (ECM) is
programmed to deactivate the lift and drive
functions and activate an alarm when a signal is
received from the level sensor.
The tilt alarm sounds when the incline of the
chassis exceeds 1.5° to the side and 3° to the front
or rear.
Use the illustrations to verify which type of level
sensor is installed and perform the procedure that
is appropriate for your machine.
Procedure 1
34
GS-30 • GS-32 • GS-46 • GS-47
Procedure 2
Procedure 3
1 X axis
2 Y axis
April 2017