Software Revision Level - Genie GRC-12 Service Manual

Hide thumbs Also See for GRC-12:
Table of Contents

Advertisement

September 2016
REV A
2-1

Software Revision Level

How to Determine the
Software Revision Level
The machine software revision level is displayed at
the ground controls LCD display.
1 Turn the key switch to the ground controls
position and pull out the red Emergency Stop
button to the on position at both ground and
platform controls.
Result: The display at the platform controls will
show "CH". See example below.
Result: The display at the ground controls will
show the machine model and hour meter
information. See example below.
Part No. 227123
2 Press the ground controls scroll down button.
Result: The ground controls LED display will
indicate the software revision and hour meter
information. After 5 seconds, the ground
controls LED display will display machine
model and hour meter information again.
See example below.
3 Push in the red Emergency Stop button to the
off position at both the ground and platform
controls and turn the key switch to the off
position.
a
b
GRC
Section 4 • Repair Procedures
GROUND CONTROLS
ground controls LCD display
ground controls scroll down button
4 - 7