Parameters
vsan vsan-id: Specifies a VSAN by its ID in the range of 1 to 3839. If you do not specify a VSAN, this
command display the topology discovery status in all VSANs.
Examples
# Display the topology discovery status in all VSANs.
<Sysname> display fcs discovery status
VSAN
Discovery Status
1
inProgress
2
completed
3
localOnly
Related commands
fcs discovery start
•
fcs discovery stop
•
display fcs database
Use display fcs database to display the local FCS database information, including IE attributes and port
attributes.
Syntax
display fcs database [ vsan vsan-id ]
Views
Any view
Predefined user roles
network-admin
network-operator
Parameters
vsan vsan-id: Specifies a VSAN by its ID in the range of 1 to 3839. If you do not specify a VSAN, this
command display the FCS database information in all VSANs.
Examples
# Display the FCS database information in all VSANs.
<Sysname> display fcs database
FCS Local Database in VSAN 1:
IE WWN
Domain ID
Management address list
Fabric name
Logical name
Information list
IE_Ports:
Interface
Fc1/0/2
: 10:00:00:11:22:00:01:01
: 0x01
: snmp://192.168.6.100
snmp://192.168.0.100
: 10:01:00:11:22:00:01:01
: IE-Sysname1
: HP# HP FF 5900CP-48XG-4QSFP+ Switch#Version 7.1.045,
ESS 2415
Port WWN
2f:15:01:11:22:00:01:01
Port type
Attached port WWNs
F_Port
2f:15:01:11:22:00:01:02
140