Encoder Input Type Setting; Output Setting For Frequency Division (Denominator); Electrical Gear At Load Side A1, A2; Electrical Gear At Motor Side B1, B2 - Delta C2000 series User Manual

Classical field oriented control ac motor drive
Hide thumbs Also See for C2000 series:
Table of Contents

Advertisement

Chapter 12 Description of Parameter SettingsC2000 Series

Encoder Input Type Setting

Settings

Output Setting for Frequency Division (denominator)

Settings
 This parameter is used to set the denominator for frequency division (for PG card EMC-PG01L or
EMC-PG01O). For example, when it is set to 2 with feedback 1024ppr, PG output will be
1024/2=512ppr.
Electrical Gear at Load Side A1
Electrical Gear at Motor Side B1
Electrical Gear at Load Side A2
Electrical Gear at Motor Side B2
Settings
0: Disable
1: Phase A leads in a forward run command and phase B leads in a reverse
run command
FWD
A
B
2: Phase B leads in a forward run command and phase A leads in a reverse
run command
FWD
A
B
3: Phase A is a pulse input and phase B is a direction input. (L =reverse
direction, H=forward direction)
FWD
A
B
4: Phase A is a pulse input and phase B is a direction input. (L=forward
direction, H=reverse direction)
FWD
A
B
5: Single-phase input
A
1~255
1~65535
REV
REV
REV
REV
164
Factory Setting: 0
Factory Setting: 1
Factory Setting: 100