Modem Status : XX Expected : XX
6
RS232C Data Real loopback interrupt request failed
LINE STATUS : XX
7
RS232C Serial port data real loopback Test failed
Line status : XX
8
RS232C Data real loopback receive failed
LINE STATUS : XX
9
RS232C Serial port data real loopback Test failed
Xmit : XX Recv : XX
10
RS232C Data real loopback transmit failed
Line status : XX

3.5.5. Audio Test

Only OK or NG

3.5.6. Customer Display Test

Only OK or NG

3.5.7. Touch Panel Test

No.
Message
1
CALTRN Command Receive Retry Out
2
File Access Error

3.5.8. Drawer Test

No.
Message
1
Already Open
2
Drawer 1 or 2 is open?

3.5.9. Ether Test

No.
Message
1
NG [ TX NOT READY ]
2
NG [ RX NOT READY ]
3
NG [ DATA ( S-XX R-XX) ]
4
NG [ TXT SIZE ERROR ]
5
Write XXXX : Read XXX NG [ EEPROM ERROR]

3.5.10. USB Test

No.
Message
1
USB device not connected
2
Low speed device connected
3
High speed device connected
4
USB device disconnected

3.5.11. Heat Run Test

None

3.5.12. Input PASSWORD (at entering Interactive Administrator Mode )

No.
Message
1
NG, Password is not correct.
Loopback Test among DSR of the modem status,
CTS, RI, and RLSD is one.
The time-out was done without generating the
interrupt of the cereal in External Loopback Test.
The line change of state interrupt went up in
External Loopback Test, and the flaming error or
the parity error or the overrunning error occurred.
Bit (Line Status Bit0 ) with received data is not one
though the reception interrupt goes up in External
Loopback Test.
In External Loopback Test, received data is not
corresponding to transmission data.
The transmission data register is not empty though
the transmission interrupt goes up in External
Loopback Test. (Line Status Bit5 )
Cause
After calibration had ended, the return code of the
CALTRN command (correction factor demand
command) was illegal.
It failed in writing the correction data in the file.
Cause
The drawer is already open.
Open the Drawer, check the state of the Drawer
Cause
The time-out was done without the transmission
OK bit becoming one after data had been
transmitted.
The time-out was done without the reception OK
bit becoming one by data receive standby.
Transmission data doesn't match to received data.
The size of received data is illegal.
It failed in writing EEPROM
Cause
The USB device is not connected.
Rorspedodebais is connected.
A high-speed device is connected.
The USB device was removed.
Cause
The input password is wrong.
57

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Js-925ws-h50Js-925ws-051Js-925ws-h52Js-925ws-050

Table of Contents