Test Program (Ediag); Initiation Method Of Test Program - Panasonic JS-925WS-010 Service Manual

Js-925 series pos workstation
Table of Contents

Advertisement

3. Test Program (eDiag)

3.1. Initiation method of test program

Before executing e-Diag, please make sure the setting of ATA/IDE configuration is "Compatible Mode".
If not, please enter the BIOS Advanced Page and change the setting of ATA/IDE configuration from
"Enhanced Mode" to "Compatible Mode".
Initiation method of ROM version 925ROM
1.
Keyboard start
The USB keyboard is connected with JS-925, and the power supply is turned on. The [F10] Insert key is
pressed while POST.
2.
Touch panel start
The power supply of JS-925 is turned on. It touches a square button on the right top of the screen while
counting the memory of POST.
3.
Automatically start
When system boots up, BIOS read and check CMOS data, which is set as "Launch Diagnostic program", so
BIOS automatically launch the diagnostic program.
When Diagnostic protram starts, it read and check COMS data to understand which mode (Auntomatically or
not) should be executed.
If CMOS data is set as "Automatically", diagnostic program have to check the CMOS data what tests should
be executed. In other words, changing CMOS data can select the test item in Auntomatic Mode.
Please refer to BIOS specification document to know better about work low
Here
Screen of LCD
20
======
======
======