  • Page 2: Table Of Contents

    Table of contents Introduction ...........................3 Important symbols ........................4 Product overview ..........................5 Standards and approvals ......................6 Product identification ........................7 Technical data common to all models ..................8 6.1 Hardware specifications ......................8 6.2 Environmental conditions ......................8 6.3 Electromagnetic compatibility (EMC) ..................9 6.4 Durability information ......................9 Technical data by model ......................10 Product dimensions ........................
  • Page 3: Introduction

    Introduction Introduction This instruction manual contains information about the installation, transportation, storage, assembly, use and maintenance of programmable displays of the HMe series. The following models are available: • HMe04: Programmable display with TFT color 4.3” widescreen display touch screen • HMe07: Programmable display with TFT color 7” widescreen display touch screen • HMe10: Programmable display with TFT color 10.1” widescreen display touch screen...
  • Page 4: Important Symbols

    Important symbols Important symbols One or more of the following symbols may be used in this documentation to indicate the type of haz- ard. DANGER Indicates a hazardous situation which, if not avoided, will result in death or serious injury. WARNING Indicates a hazardous situation which, if not avoided, could result in death or serious injury. CAUTION Indicates a hazardous situation which, if not avoided, could result in serious or moderate injury. Notice Indicates a property damage message.
  • Page 5: Product Overview

    Product overview Product overview The HMe series programmable displays combine state-of-the-art features and top performance with an outstanding design. They are the ideal choice for all demanding HMI applications including factory and building automation. The HMe series programmable displays have been designed to run the HMWIN software. • Compatible with HMWIN Studio. • Full vector graphic support. Native support of SVG graphic objects, transparency and alpha blend- ing. • Screen object dynamics: control visibility and transparency, move, resize, rotate any object on screen. Change properties of basic and complex objects. • Multilanguage applications with TrueType fonts. Easily create, install and maintain applications in multiple languages to meet global requirements. • Data display in numerical, text, bargraph, analog gauges and graphic image formats. • Rich set of state-of-the-art HMI features: data acquisition and logging, trend presentation, alarm han- dling, scheduler and timed actions (daily and weekly schedulers, exception dates), recipes, security and user management, email and RSS feeds. • Wide selection of communication drivers available with multiple-driver communication capability. • Remote monitoring and control with client/server functionality. • On-line and Off-line simulation with HMWIN Studio. • Powerful scripting language for automated HMI applications. Efficient script debugger improves pro- ductivity in application development. • Rich gallery of vector symbols and objects.
  • Page 6: Standards And Approvals

    Standards and approvals Standards and approvals The products have been designed for use in an industrial environment in compliance with the 2014/30/ EU EMC Directive. The products have been designed in compliance with: EN 61000-6-4 EN 55011 Class A EN 61000-6-2 EN 61000-4-2 EN 61000-4-3 EN 61000-4-4 EN 61000-4-5 EN 61000-4-6 The installation of these products into the residential, commercial and light-industrial environments is allowed only in the case that special in measures are taken in order to ensure conformity to EN 61000-6-3. In compliance with the above regulations the products are CE marked.
  • Page 7: Product Identification

    Product identification Product identification The product may be identified through a plate attached to the rear cover. You will have to know the product type you are using for correct usage of the information contained in the guide. The following information is provided by the plate: • Product model name • Product part number • Year/week of production • Version ID of the product • Serial number...
  • Page 8: Technical Data Common To All Models

    Technical data common to all models Technical data common to all models Hardware specifications Touch screen technology Resistive Real-time clock back-up Supercapacitor Fuse Automatic Serial port RS232, RS485, RS422 software configurable Recipe memory Flash Real-time clock Clock/calendar with supercapacitor back-up Accuracy real-time clock <100ppm (at 25°C) Environmental conditions Operating temperature 0 to +50°C EN 60068-2-14 (surrounding air temperature) Storage temperature -20 to +70°C EN 60068-2-14...
  • Page 9: Electromagnetic Compatibility (Emc)

    Technical data common to all models Electromagnetic compatibility (EMC) Radiated disturbance test Class A EN 55011 Electrostatic discharge immunity test 8kV (air electrostatic discharge) EN 61000-4-2 4kV (contact electrostatic discharge) Radiated, radio frequency, 80MHz–1GHz, 10V/m EN 61000-4-3 electromagnetic field immunity test 1.4–2GHz, 3V/m 2–2.7GHz, 1V/m Burst immunity test ±2KV DC power port EN 61000-4-4 ±1KV signal line Surge immunity test ±0.5KV DC power port (line to earth) EN 61000-4-5 ±0.5KV DC power port (line to line) ±1KV signal line (line to earth) Immunity to conducted disturbances 0.15–80MHz, 10V EN 61000-4-6 inducted by radio frequency field...
  • Page 10: Technical Data By Model

    Technical data by model Technical data by model Model HMe04 HMe07 HMe10 Display / Backlight TFT Color / LED Colors Resolution 480 x 272 800 x 480 1024 x 600 Display size (inch) 4.3 widescreen 7” widescreen 10.1” widescreen Dimming User memory flash 60MB 256MB DDR 512MB DDR Serial port RS232, RS485, RS422 DB9 female software RS232, RS485, configurable RS422 software configurable Ethernet port 10/100Mbit USB port Host interface V2.0, max. 500mA Real-time clock Voltage...
  • Page 11: Product Dimensions

    Product dimensions Product dimensions HMe04 Model HMe04 136mm 96mm 147mm 107mm 29mm...
  • Page 12: Hme07

    Product dimensions HMe07 Model HMe07 176mm 136mm 187mm 147mm 29mm...
  • Page 13: Hme10

    Product dimensions HMe10 Model HMe10 271mm 186mm 282mm 197mm 29mm...
  • Page 14: Installation

    Installation Installation Installation environment In order to meet the front panel protection classifications, proper installation procedure must be followed: • The borders of the cutout must be flat. • Each fixing screw must be tightened until the plastic bezel corner get in contact with the panel. • The cutout for the panel must be of the dimensions indicated in this manual. The product is not intended for continuous exposure to direct sunlight. This might accelerate the aging process of the front panel film. The product is not intended for installation in contact with corrosive chemical compounds. Check the resistance of the front panel film to a specific compound before installation. Do not use tools of any kind (screwdrivers, etc.) to operate the touch screen of the product. The IP66 is guaranteed only if: • The max. deviation from the plane surface to the cutout is ≤0.5mm • The thickness of the case where the product is mounted is from 1.5mm to 6mm • The max. surface roughness where the gasket is applied is ≤120μm. (1) Installation cutout...
  • Page 15: Installation Procedure

    Installation Installation procedure For details on installation, please refer to the Installation Guide provided with the product. Place the fixing brackets as shown in the following figure. Notice Make sure to screw each fixing screw until the bezel corner gets in contact with the panel. Tightening torque: 75 Ncm...
  • Page 16: Connections

    Connections 10. Connections 10.1 HMe04 (1) Serial port (2) Ethernet port (3) USB port (4) Power supply...
  • Page 17: Hme07

    Connections 10.2 HMe07 (1) Serial port (2) Ethernet port (3) USB port (4) Power supply...
  • Page 18: Hme10

    Connections 10.3 HMe10 (1) Serial port (2) Ethernet port (3) USB port (4) Power supply...
  • Page 19: Serial Port

    Connections 10.4 Serial port The serial port is used to communicate with the PLC or with another type of controller. Standards available for the signals in the PLC port connector are: RS232, RS422, RS485. Use the corresponding communication cable for the connection. The serial port is software programmable. Make sure you select the appropriate interface in the pro- gramming software. RS232 RS422, RS485 Description Description CHA- Serial port CHB- +5V output +5V output CHB+ CHA+ For RS485, pins 4-3 and 8-7 must be connected externally. 10.5 Ethernet port The Ethernet port has two LED status indicators. They work as shown in the following table. (1) Green LED (2) Yellow LED Description No LAN cable connected BLINKING (link active) LAN cable connected with 100Mbit/s link BLINKING (link active) LAN cable connected with 10Mbit/s link...
  • Page 20: Power Supply, Grounding, And Shielding

    Connections 10.6 Power supply, grounding, and shielding The power supply terminal block is shown in the following figure. DC power connector - AWG24 wire size - R/C terminal blocks (XCFR2), female pitch 5.08mm, torque 4.5 lb-in NOTE Make sure that the power supply has sufficient power capacity for the operation of the product. The product must always be grounded to earth. Grounding helps limit the effects of noise due to elec- tromagnetic interference on the control system. Use terminal 3 on the power supply terminal block earth connection. The power supply circuit may be floating or grounded. In the latter case, the power source common is connected as indicated with a dashed line in the following figure. When using the floating power scheme, note that internally the power common is connected to the ground with a 1MΩ resistor in parallel with a 4,7nF capacitor. The power supply must have double or reinforced insulation. The suggested wiring for the power sup- ply is shown in the following figure. All the electronic devices in the control system must be properly grounded. Grounding must be per- formed according to applicable regulations.
  • Page 21: Cleaning Faceplates

    Cleaning faceplates 11. Cleaning faceplates The product must be cleaned only with a soft cloth and neutral soap product. Do not use solvents. 12. Getting started The HMe series panels must be programmed with the programming software HMWIN Studio (starting from v2.6), a Windows application. There are two options to transfer a HMWIN application project to a panel: Ethernet Connect the panel via the Ethernet interface to a personal computer running the HMWIN Studio software. Select “Run/Download to target” in HMWIN Studio. Make sure that the firewall policy is configured in a way that allows HMWIN Studio to access the network. Create an update package using the HMWIN Studio software and copy it to an USB flash drive.
  • Page 22: System Settings Tool

    System settings tool 13. System settings tool 13.1 Introduction The HMe series panels have a system settings interface to allow the configuration of system options. The user interface of “System Settings” is based on HTML pages accessible locally on HMI or remote using a web browser, e.g. Chrome v44 or higher on port 443 (https://IP/machine_config). The default username is “admin”, and the default password is “admin”. Use the navigation menu on the left side of the screen to browse through the available options. On the left side, the selected menu item is highlighted. The right side shows related information and settings. Based on the size of the panel, menu and content of the selected menu item may not be displayed next to each other on the screen. The system settings interface has two operating modes: User mode HMWIN runtime is running or the status of the HMI panel is set to “factory default”. System mode HMWIN runtime is not running or there is a software failure. The system mode includes all options available in user mode. In addition, the system mode offers commands dedicated to system upgrade and recovery which are not available in user mode. 13.2 Activation of system settings in user mode HMWIN runtime Touch the “System Setting” button on the HMI panel. not running HMWIN runtime To activate the system settings in user mode, touch and hold any unused area running of the touch screen for a few seconds to access the context menu. The default...
  • Page 23: Activation Of System Settings In System Mode

    System settings tool 13.3 Activation of system settings in system mode Normal If HMWIN runtime is not running: operation Touch the “System Setting” button on the HMI panel to open the system settings in user mode. Select “Restart” > “Config OS” to reboot in system mode. If HMWIN runtime is running: To activate the system settings in user mode, touch and hold any unused area of the touch screen for a few seconds to access the context menu. The default holding time is 2 seconds. Select “Restart” > “Config OS” to reboot in system mode. Recovery If the HMI panel is not responsive, tap on the surface of the touch screen during operation the power-up phase of the panel. The tapping frequency must be high. Start tap- ping the touch screen as soon as power has been supplied to the panel. The message “TAP-TAP DETECTED” appears when the operating sequence has been recognized. Release the touch screen to boot in user mode without running HMWIN runtime or touch and hold the touch screen for a few seconds. Then select “Restart” > “Config OS” to boot in system mode. 13.4 Options available in system settings The following important basic setting options of the panel are available: Language Configure the language used for the system setting menu only. System Shows information about platform, status and timers (e.g. system on time, backlight on time). Logs Enable persistent log for BSP and allows to export it.
  • Page 24: Touch Screen Calibration

    Touch screen calibration 14. Touch screen calibration The HMe series panels support the calibration of the interface. To start calibration do the following: • Tap on the surface of the touch screen during the power-up phase of the panel. The tapping frequen- cy must be high. Start tapping the touch screen as soon as power has been supplied to the panel. The message “TAP-TAP DETECTED” appears when the operating sequence has been recognized. • Release the touch screen and wait a few seconds until the message “ENTERING SYSTEM SET- TINGS” appears. • Touch and hold the touch screen for a few seconds to select “TOUCHSCREEN CALIBRATION”. 15. Unpacking and packing instructions To repack the product, please follow the instructions backwards.
  • Page 25: Record Of Changes

    Record of changes 16. Record of changes Manual No. Date Description of changes ACGM0195V1EN September 2017 First edition based on the eSMART Series Operating Instructions version 1.01 ACGM0195V2EN June 2018 Added the model HMe04 Updated the phone number of the Polish office and deleted the fax number on the back page ACGM0195V3EN February 2019 Removed the pictures of the rating plates Added “Important symbols” page Distributed by Panasonic Electric Works Europe AG www.panasonic-electric-works.com Subject to change without notice. The information contained in this document is provided for informational purposes only. While efforts were made to verify the accuracy of the information contained in this documentation, it is provided “as is” without warranty of any kind. Third-party brands and names are the property of their respective owners.
  • Page 26 Filial Nordic, Knarrarnäsgatan 15, 164 40 Kista, Sweden, Tel. +46 859476680, Fax +46 859476690, www.panasonic-electric-works.se Panasonic Eco Solutions Nordic AB Jungmansgatan 12, 21119 Malmö, Tel. +46 40 697 7000, Fax +46 40 697 7099, www.panasonic-fi re-security.com Poland Panasonic Electric Works Polska sp. z o.o ul.