App. 10 Using The Neutral Point Of A 3-Phase 400 V Ac Class Power Supply For Inputting A 1-Phase 200 V Ac Class Power Supply - Mitsubishi MR-JE-10B Instruction Manual

Mr-je series
Table of Contents

Advertisement

APPENDIX
App. 10 Using the neutral point of a 3-phase 400 V AC class power supply for inputting a
1-phase 200 V AC class power supply
CAUTION
You can use the neutral point of a 3-phase 400 V AC class power supply to input a 1-phase 200 V AC class
power supply to the servo amplifier.
If necessary, use a step-down transformer to decrease the power supply voltage to 200 V AC to 240 V AC.
(1) For MR-JE-10B to MR-JE-100B
Do not input a 3-phase 400 V AC class power supply directly to the 200 V class
servo amplifier. Otherwise, it may cause a malfunction.
3-phase
400 V AC class
Do not connect anything.
3-phase
400 V AC class
Neutral
point
200 V AC to 240 V AC (Note 1)
Do not connect anything.
Note 1. If necessary, use a step-down transformer to decrease the power supply voltage to 200 V AC
to 240 V AC.
2. Connect the 1-phase 200 V AC to 240 V AC power supply to L1 and L3. One of the
connecting destinations is different from MR-JE-200B servo amplifier's.
Off
Emergency
stop switch
MCCB
MC
Emergency
stop switch
MCCB
App. - 20
On
MC
MC
SK
Alarm
Servo amplifier
CNP1
Off
On
MC
Alarm
Servo amplifier
CNP1 (Note 2)
MC
L1
L2
L3
MC
SK

Hide quick links: