11. OPTIONS AND PERIPHERAL EQUIPMENT

11.3 Junction terminal block PS7DW-20V14B-F (recommended)

(1) Usage
Always use the junction terminal block (PS7DW-20V14B-F (Toho Technology)) with the option cable
(MR-J2HBUS_M) as a set. A connection example is shown below.
Ground the junction terminal block cable on the junction terminal block side with the supplied cable
clamp fitting (AERSBAN-ESET). For the use of the cable clamp fitting, refer to section 11.10, (2) (c).
(2) Connection diagram of MR-J2HBUS_M cable and junction terminal block
Servo amplifier
Cable clamp
(AERSBAN-ESET)
CN3
MR-J2HBUS_M
Servo amplifier
CN3
(Note) MR-J2HBUS_M
1
1
2
2
DOCOM
3
3
4
4
5
5
6
6
7
7
8
8
9
9
DICOM
10
10
11
11
12
12
MBR
13
13
14
14
15
15
16
16
17
17
18
18
19
19
EM2
20
20
SD
Shell
Shell
Connector: 52316-2019 (Molex)
Shell kit: 52370-2070 (Molex)
Note. A symbol indicating the cable length is put in _.
05: 0.5 m
1: 1 m
5: 5 m
11 - 17
Junction terminal block
PS7DW-20V14B-F
Junction terminal block
PS7DW-20V14B-F
CN
Terminal block
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
9
9
10
10
11
11
12
12
13
13
14
14
15
15
16
16
17
17
18
18
19
19
20
20
Shell Shell
1
2
3
DOCOM
4
5
6
7
8
9
10
DICOM
11
12
13
MBR
14
15
16
17
18
19
20
EM2
E
SD

Hide quick links: