Response Level Setting In Auto Tuning Mode - Mitsubishi MR-JE-10B Instruction Manual

Mr-je series
Table of Contents

Advertisement

6. NORMAL GAIN ADJUSTMENT

6.3.4 Response level setting in auto tuning mode

Set the response of the whole servo system by [Pr. PA09]. As the response level setting is increased, the
trackability to a command improves and settling time decreases, but setting the response level too high will
generate vibration. Set a value to obtain the desired response level within the vibration-free range.
If the response level setting cannot be increased up to the desired response because of machine resonance
beyond 100 Hz, filter tuning mode selection in [Pr. PB01] or machine resonance suppression filter in [Pr.
PB13] to [Pr. PB16], and [Pr. PB46] to [Pr. PB51] may be used to suppress machine resonance.
Suppressing machine resonance may allow the response level setting to increase. Refer to section 7.1.1 and
7.1.2 for settings of the adaptive tuning mode and machine resonance suppression filter.
[Pr. PA09]
Setting
value
Response
1
2
response
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
Middle
19
response
20
Machine characteristic
Guideline for the
machine resonance
frequency [Hz]
2.7
Low
3.6
4.9
6.6
10.0
11.3
12.7
14.3
16.1
18.1
20.4
23.0
25.9
29.2
32.9
37.0
41.7
47.0
52.9
59.6
Reference
(setting
Setting
value of
value
Response
MR-J3)
21
22
response
23
24
1
25
2
26
3
27
4
28
5
29
6
30
7
31
8
32
9
33
10
34
11
35
12
36
13
37
14
38
15
39
response
16
40
6 - 22
Machine characteristic
Guideline for the
machine resonance
frequency [Hz]
67.1
Middle
75.6
85.2
95.9
108.0
121.7
137.1
154.4
173.9
195.9
220.6
248.5
279.9
315.3
355.1
400.0
446.6
501.2
High
571.5
642.7
Reference
(setting
value of
MR-J3)
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents