4.7.5.3 Hardware Temperature
This page allows you to:
view current system temperature
set several temperature and time thresholds (see description in the following table)
From the Maintenance menu, click on Fault Management and then Hardware Temp. The
following page is displayed:
Label
Modify
Current Temperature (
Up Shift Threshold (
Up Shift Time (Sec)
Down Shift Threshold (
Down Shift Time (Sec)
Fan ON Threshold (
Fan Shift Time (Sec)
Temperature Configuration
Click on this button to submit the update once you have entered all
the new threshold values.
o
C)
This field shows the current system temperature.
The system will produce notification (alarm) when the monitored
o
C)
system temperature is higher than Up Shift Threshold (-55~85
over Up Shift Time (1~255 sec).
Refer to the description for Up Shift Threshold.
The system will produce notification (alarm) when the monitored
o
C)
system temperature is lower than Down Shift Threshold (-55~85
for over Down Shift Time (1~255 sec).
Refer to the description for Down Shift Threshold.
FAN Enable temperature threshold (-40~15
o
C)
temperature is higher than the threshold, the fan will be turned on
automatically.
This field shows the elapsed time since the FAN was turned on.
Description
- 188 -
o
C) for
o
o
C). When the system
C)