Install And Connect The Brake Relay - Pm240-2 Power Module - Siemens SINAMICS G120 Operating Instructions Manual

Low voltage converter with the cu240b-2 and cu240e-2 control units
Hide thumbs Also See for SINAMICS G120:
Table of Contents

Advertisement

4.5.4.5

Install and connect the Brake Relay - PM240-2 Power Module

Installing the Brake Relay
● FSA ... FSC: Install the Brake Relay next to the Power Module.
● FSD ... FSF: Install the Brake Relay at the rear of the lower shield plate. Attach the Brake
Relay before you install the shield plate.
Connecting the Brake Relay to the inverter
The connector for the Brake Relay is located at the front of the Power Module. Lay the cable
harness for the Brake Relay in the cable routing.
Converter with the CU240B-2 and CU240E-2 Control Units
Operating Instructions, 01/2016, FW V4.7 SP6, A5E34259001B AC
4.5 Connecting the line supply, motor, and inverter components
Installing
89