Daikin RMXS-L Series Service Manual page 85

Multi-split type air conditioners
Hide thumbs Also See for RMXS-L Series:
Table of Contents

Advertisement

SiUS181631EA
FVXS Series
airflow limit
airflow limit
3-D Airflow
CTXG, CTXS, FTXS Series
Alternative repetition of vertical and horizontal swing motions enables uniform air-conditioning of
the entire room.
When the horizontal swing and vertical swing are both set to automatic operation, the airflow
becomes 3-D airflow. The horizontal and vertical swing motions are alternated and the airflow
direction changes in the order shown in the following diagram.
(1) The louvers move from the right to the left.
(2) The flaps move downward.
(3) The louvers move from the left to the right.
(4) The flaps move upward.
COMFORT
CTXG, CTXS-L, FTXS-L Series
The horizontal blades (louvers) are controlled not to blow the air directly at the people in the room.
AIRFLOW
Operation
The airflow will be in the upward direction while in cooling operation and in the downward direction
while in heating operation, which will provide a comfortable wind that will not come in direct contact
with people.
Functions and Control
Flap (up and down)
Cooling/Dry
Upward
OFF
(R6831)
Upward
ON
(R6832)
CTXG, CTXS, FTXS, CDXS, FDXS, FVXS Series Functions
Heating
(R6829)
(R6830)
(1)
(2)
(3)
(4)
(R19554)
75