Daikin RMXS-L Series Service Manual page 55

Multi-split type air conditioners
Hide thumbs Also See for RMXS-L Series:
Table of Contents

Advertisement

SiUS181631EA
Back View
R5T : Thermistor (suction pipe 2)
(Marking : green)
R7T : Thermistor (liquid pipe)
(Marking : blue)
Refrigerant Circuit
Functional Parts Layout
R6T : Thermistor (subcooling heat
exchanger gas pipe)
(Marking : white)
R3T : Thermistor (suction pipe 1)
(Marking : red)
R1T : Thermistor (outdoor
temperature)
(Marking : yellow)
R4T : Thermistor (outdoor heat
exchanger)
(Connector : blue)
(R17940)
45

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents