Daikin RMXS-L Series Service Manual page 233

Multi-split type air conditioners
Hide thumbs Also See for RMXS-L Series:
Table of Contents

Advertisement

SiUS181631EA
Troubleshooting
Check No.11
Refer to P.225
Troubleshooting
Be sure to turn off the power switch before connecting or disconnecting
Caution
connectors, or parts may be damaged.
Push and hold the RESET
button on the outdoor unit
PCB for 5 seconds.
Does the
malfunction occur
again?
YES
Check the indoor unit - BP
unit connection wires.
Is there any wiring
error?
NO
Is service
monitor on the
indoor unit PCB
blinking?
Blink
Check the HAP on the outdoor
unit.
Continuously ON or OFF
Is HAP blinking?
Blink
Check the voltage of the
indoor unit - BP unit
connection wires between No.
1 and No. 2, and between No
2 and No. 3.
Is the voltage 0 V?
NO
Check No. 11
Check power supply
waveform.
Is there any
disturbance?
YES
Troubleshooting for Branch Provider (BP) Unit
NO
YES
Continuously ON or OFF
Turn the power off and then
on again.
Is service
monitor on the
indoor unit PCB
blinking?
Blink
Turn the power off and then
on again.
Is HAP blinking?
Blink
YES
NO
Normal
(Address Setting was not
conducted)
Correct the indoor unit - BP unit
connection wires.
Continuously
ON or OFF
Defective indoor unit PCB or
malfunction of power supply
system.
Resets normally.
Could be other causes than
malfunction (for example, noise
etc.).
Continuously
ON or OFF
Defective BP unit PCB or
malfunction of power supply
system.
Could be other causes than
malfunction (for example, noise
etc.).
Replace the connection wires
between the indoor and BP units.
Replace the indoor unit PCB.
Locate the cause of the
disturbance of the power supply
waveform, and correct it.
(R24603)
223

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents