Daikin RMXS-L Series Service Manual page 26

Multi-split type air conditioners
Hide thumbs Also See for RMXS-L Series:
Table of Contents

Advertisement

Specifications
Model
Rated Capacity
Front Panel Color
H
M
Airflow Rate
L
SL
Type
Fan
Motor Output
Speed
Air Direction Control
Air Filter
Running Current (Rated)
Power Consumption (Rated)
Power Factor (Rated)
Temperature Control
Dimensions (H × W × D)
Packaged Dimensions (H × W × D)
Weight (Mass)
Gross Weight (Gross Mass)
Sound Pressure
H / M / L / SL
Level
Sound Power Level
Heat Insulation
Liquid
Piping
Gas
Connections
Drain
Drawing No.
16
Cooling
643 (18.2)
494 (14.0)
cfm
(m³/min)
350 (9.9)
328 (9.3)
W
Steps
A
0.57 - 0.51
W
%
58.2 - 58.0
in. (mm)
in. (mm)
Lbs (kg)
Lbs (kg)
dB(A)
51 / 44 / 37 / 34
dB
in. (mm)
in. (mm)
in. (mm)
FTXS24LVJU
24 kBtu/h Class
White
Cross Flow Fan
48
5 Steps, Quiet, Auto
Right, Left, Horizontal, Downward
Removable, Washable, Mildew Proof
69 - 68
Microcomputer Control
13-3/8 × 41-5/16 × 9-3/4 (340 × 1,050 × 248)
13 × 45-11/16 × 16-7/8 (331 × 1,160 × 429)
31 (14)
46 (21)
67
Both Liquid and Gas Pipes
φ
φ
1/4 (
6.4)
φ
φ
5/8 (
15.9)
φ
φ
5/8 (
16)
3D075045A
SiUS181631EA
60 Hz, 208 - 230 V
Heating
699 (19.8)
572 (16.2)
445 (12.6)
403 (11.4)
0.57 - 0.51
69 - 68
58.2 - 58.0
48 / 42 / 37 / 34
64
Conversion Formulae
kcal/h = kW × 860
Btu/h = kW × 3412
cfm = m³/min × 35.3
Specifications

Hide quick links:

Advertisement

Table of Contents
loading