Models
Reactor 2 E-30 and E-30 Elite
All elite systems include fluid inlet sensors, Graco InSite
part numbers, see
Accessories, page 11
Model
Proportioner ★
Maximum Fluid Working
Pressure psi (MPa, bar)
Approximate Output per
Cycle (A+B) gal. (liter)
Max Flow Rate lb/min
(kg/min)
Total System Load †
(Watts)
Configurable Voltage
Phase
Full Load Peak Current* 78
Fusion AP Package
(Gun Part No.)
Fusion CS Package
(Gun Part No.)
Probler P2 Package
(Gun Part No.)
Heated Hose
50 ft (15 m)
Heated Whip Hose
10 ft (3 m)
Graco Insite
™
Fluid Inlet Sensors (2)
Full load amps with all devices operating at
*
maximum capabilities. Fuse requirements
at various flow rates and mix chamber sizes
may be less.
Total system watts used by system, based on
maximum heated hose length for each unit.
• E–30 and E–XP2 series: 310 ft (94.5 m)
maximum heated hose length, including
whip hose.
333023D
Base Model
E-30, 10 kW
E-30, 15 kW
272010
272011
2000 (14, 140)
2000 (14, 140)
0.0272 (0.1034)
0.0272 (0.1034)
30 (13.5)
30 (13.5)
17,900
23,000
230
230
380
230
1Ø
3Ø∆
3ØY
1Ø
50
34
100
AP2010
AP2011
(246102)
(246102)
CS2010
CS2011
(CS02RD)
(CS02RD)
P22010
P22011
(GCP2R2)
(GCP2R2)
24K240 (scuff
24K240 (scuff
guard)
guard)
246050
246050
, and Xtreme-Wrap 50 ft (15 m) heated hose. For
™
Elite, 10 kW
272110
2000 (14, 140)
0.0272 (0.1034)
30 (13.5)
17,900
230
380
230
230
3Ø∆
3ØY
1Ø
3Ø∆
62
35
78
50
AP2110
(246102)
CS2110
(CS02RD)
P22110
(GCP2R2)
24Y240 (Xtreme-
Wrap)
246050
✓
✓
★
See
Approvals, page
Packages include gun, heated hose, and
whip hose. Elite packages also include
Graco InSite and fluid inlet sensors.
Models
Elite Model
Elite, 15kW
272111
2000 (14, 140)
0.0272 (0.1034)
30 (13.5)
23,000
380
230
230
380
3ØY
1Ø
3Ø∆
3ØY
34
100
62
35
AP2111
(246102)
CS2111
(CS02RD)
P22111
(GCP2R2)
24Y240 (Xtreme-
Wrap)
246050
✓
✓
11.
9