Maintenance; Preventative Maintenance Schedule; Proportioner Maintenance - Graco Reactor 2 E-XP2 Operation

Proportioning systems
Hide thumbs Also See for Reactor 2 E-XP2:
Table of Contents

Advertisement

Maintenance

Maintenance
Prior to performing any maintenance procedures,
follow
Pressure Relief Procedure, page

Preventative Maintenance Schedule

The operating conditions of your particular system
determine how often maintenance is required.
Establish a preventive maintenance schedule by
recording when and what kind of maintenance is
needed, and then determine a regular schedule for
checking your system.

Proportioner Maintenance

Wet Cup
Check the wet cup daily. Keep it 2/3 full with Graco
Throat Seal Liquid (TSL
not overtighten packing nut/wet cup.
Packing Nuts
Do not overtighten packing nut/wet cup. Throat u-cup
is not adjustable.
Fluid Inlet Strainer Screens
Inspect fluid inlet strainer screens daily, see
Flush Inlet Strainer Screen, page
54
52.
) or compatible solvent. Do
®
55.
Grease Circulation Valves
Grease circulation valves (SA and SB) with Fusion
grease (117773) weekly.
SA
ISO Lubricant Level
Inspect ISO lubricant level and condition
daily. Refill or replace as needed. See
Pump Lubrication System, page
Moisture
To prevent crystallization, do not expose component
A to moisture in air.
Gun Mix Chamber Ports
Clean gun mix chamber ports regularly. See gun
manual.
Gun Check Valve Screens
Clean gun check valve screens regularly. See gun
manual.
Dust Protection
Use clean, dry, oil-free compressed air to prevent
dust buildup on control modules, fans, and motor
(under shield).
Vent Holes
Keep vent holes on bottom of electrical cabinet open.
SB
ti10955a
56.
333023D

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Reactor 2 e-30

Table of Contents