Fluid Circulation

Fluid Circulation

Circulation Through Reactor

NOTICE
To prevent equipment damage, do not circulate
fluid containing a blowing agent without consulting
with your material supplier regarding fluid
temperature limits.
NOTE: Optimum heat transfer is achieved at lower
fluid flow rates with temperature set points at desired
drum temperature. Low temperature rise deviation
errors may result.
To circulate through gun manifold and preheat hose,
see
Circulation Through Gun Manifold, page
1. Follow
Startup, page
To avoid injection injury and splashing, do not
install shutoffs downstream of the PRESSURE
RELIEF/SPRAY valve outlets (BA, BB). The
valves function as overpressure relief valves
when set to SPRAY
open so valves can automatically relieve
pressure when machine is operating.
2. See
Typical Installation, with system fluid
manifold to drum circulation, page
circulation lines back to respective component
A or B supply drum. Use hoses rated at the
maximum working pressure of this equipment.
See
Technical Specifications, page
44
45.
41.
. Lines must be
14. Route
65.
3. Set PRESSURE RELIEF/SPRAY valves (SA,
SB) to PRESSURE RELIEF/CIRCULATION
4. Set temperature targets. See
5. Press
to circulate fluid in jog mode until
A and B temperatures reach targets. See
Jog Mode, page 45
jog mode.
6. Press
to turn on the hose heat zone.
7. Turn on the A and B heat zones. Wait until the
fluid inlet valve temperature gauges (FV) reach
the minimum chemical temperature from the
supply drums.
8. Exit jog mode.
9. Set PRESSURE RELIEF/SPRAY valves (SA,
SB) to SPRAY
Targets, page
for more information about
.
333023D
.