Technical Specifications
Reactor 2 E-30 and E-XP2 Proportioning System
Maximum Fluid Working Pressure
E-30
E-XP2
Maximum Fluid Temperature
E-30
E-XP2
Maximum Flow Rate
E-30
E-XP2
Maximum Heated Hose Length
Length
Output per Cycle
ISO and RES
E-30
E-XP2
Operating Ambient Temperature Range
Temperature
Heater Power
E-30 10 kw
E-30, 15 kw
E-XP2 15 kw
Sound Pressure
Sound Pressure measured per ISO-9614–2.
E-30
Measured from 3.1 ft (1 m), at
1000 psi (7 MPa, 70 bar), 3 gpm
(11.4 lpm)
E-XP2
Measured from 3.1 ft (1 m), at
3000 psi (21 MPa, 207 bar), 1 gpm
(3.8 lpm)
333023D
U.S.
2000 psi
3500 psi
150°F
190°F
30 lb/min
2 gpm
310 ft
0.0272 gal.
0.0203 gal.
20° to 120°F
10,200 Watts
15,300 Watts
15,300 Watts
87.3 dBA
79.6 dBA
Technical Specifications
Metric
14 MPa, 140 bar
24.1 MPa, 241 bar
66°C
88°C
13.5 kg/min
7.6 lpm
94 m
0.1034 liter