Spraying - Graco Reactor 2 E-XP2 Operation

Proportioning systems
Hide thumbs Also See for Reactor 2 E-XP2:
Table of Contents

Advertisement

Spraying

Spraying
The Fusion AP gun is shown.
1. Engage gun piston safety lock and close gun
fluid inlet valves A and B.
Fusion
2. Attach gun fluid manifold. Connect gun air line.
Open air line valve.
3. Adjust the gun air regulator on the proportioner
control panel to desired gun air pressure. Do not
exceed 130 psi (0.2 MPa, 2 bar).
4. Set PRESSURE RELIEF/SPRAY valves (SA,
SB) to SPRAY
5. Verify heat zones are on and temperatures are
on target, see
Home screen, page
46
Probler
.
36.
6. Open fluid inlet valve located at each pump inlet.
7. Press
to start motor and pumps.
8. Check fluid pressure gauges (GA, GB) to
ensure proper pressure balance. If imbalanced,
reduce pressure of higher component by
slightly turning PRESSURE RELIEF/SPRAY
valve for that component toward PRESSURE
RELIEF/CIRCULATION
balanced pressures.
until gauges show
333023D