Starting The Hybrid System When The 12-Volt Battery Is Discharged; Charging The 12-Volt Battery; When The 12-Volt Battery Is Removed Or Discharged - Lexus RX 450H Owner's Manual

Hide thumbs Also See for RX 450H:
Table of Contents

Advertisement

570
7-2. Steps to take in an emergency
Start the engine of the second vehicle. Increase the engine speed slightly and
6
maintain at that level for approximately 5 minutes to recharge the 12-volt bat-
tery of your vehicle.
Open and close any of the doors of your vehicle with the power switch off.
7
Maintain the engine speed of the second vehicle and start the hybrid system
8
of your vehicle by turning the power switch to ON mode.
Make sure the "READY" indicator comes on. If the indicator light does not
9
come on, contact your Lexus dealer.
Once the hybrid system has started, remove the jumper cables in the exact
10
reverse order from which they were connected.
Close the exclusive jump starting terminal cover, and reinstall the fuse box
11
cover to its original position.
Once the hybrid system starts, have the vehicle inspected at your Lexus dealer
as soon as possible.

Starting the hybrid system when the 12-volt battery is discharged

The hybrid system cannot be started by push-starting.
To prevent 12-volt battery discharge
Turn off the headlights and the audio system while the hybrid system is off.
Turn off any unnecessary electrical components when the vehicle is running at a low
speed for an extended period, such as in heavy traffic.

Charging the 12-volt battery

The electricity stored in the 12-volt battery will discharge gradually even when the vehicle
is not in use, due to natural discharge and the draining effects of certain electrical appli-
ances. If the vehicle is left for a long time, the 12-volt battery may discharge, and the
hybrid system may be unable to start. (The 12-volt battery recharges automatically while
the hybrid system is operating.)

When the 12-volt battery is removed or discharged

In some cases, it may not be possible to unlock the doors using the smart access system
with push-button start when the 12-volt battery is discharged. Use the wireless remote
control or the mechanical key to lock or unlock the doors.
The hybrid system may not start on the first attempt after the 12-volt battery has
recharged but will start normally after the second attempt. This is not a malfunction.
The power switch mode is memorized by the vehicle. When the 12-volt battery is
reconnected, the system will return to the mode it was in before the 12-volt battery was
discharged. Before disconnecting the 12-volt battery, turn the power switch off.
If you are unsure what mode the power switch was in before the 12-volt battery dis-
charged, be especially careful when reconnecting the 12-volt battery.
The power back door must be initialized. (→P. 150)