SiBE04-808_B
Step
3
Remove the washer-
fitted nut of the outdoor
fan.
Remove the lower 2
4
screws from the fan
motor first.
Then, remove the upper
5
2 screws.
Removal Procedure
Procedure
Outdoor fan
Outdoor Unit - RK(X)S50G2V1B, ARXS50G2V1B
The screw has reverse
winding.
Nut size: M6
(R5262)
When reassembling, align
with D-cut section of the
motor shaft.
(R5263)
Be sure to remove the lower
screws first. If the upper
screws are removed first, the
fan motor, the center of
gravity of which is toward the
front, may tilt down or fall,
getting you injured.
Fan motor
(R5264)
Points
10 mm
(R12236)
mark of the outdoor fan
270