Indoor Unit
Step
4
Detach the pivot from
the interlock shaft for
vertical blades with a
flat screwdriver.
Remove the swing
5
motor unit.
Detach the interlock
6
shaft from the swing
motor with a flat
screwdriver.
Remove the vertical
7
blade interlock with a
flat screwdriver.
179
Procedure
Vertical blade ASSY
Interlock shaft
Vertical blade interlock
Pivot
Interlock
shaft
(R12270)
Swing motor unit
(R8126)
(R8127)