Daikin G-Series Service Manual page 195

Inverter pair wall mounted type
Hide thumbs Also See for G-Series:
Table of Contents

Advertisement

SiBE04-808_B
Step
2
Loosen the lock screw
and remove the fan
rotor.
3
Press the bearing
ASSY from outside.
Remove the bearing.
4
Removal Procedure
Procedure
Lock screw
When reassembling the fan
rotor, provide as much as
5 mm of play between the
side face of the rotor and the
bottom frame.
Side face of rotor
Fan motor
(R8120)
(1) Insert the fan motor with
approx. 5 mm left.
(2) Tighten the screw until it
stops. Then turn the screw
in one scroll.
(R8121)
(3) Move the fan rotor and
confirm the fan motor and
the fan rotor are installed
appropriately.
(4) Tighten the screw
completely if appropriate.
(5) If not appropriate, go back to
(1).
(R8122)
Indoor Unit
Points
Side face of
bottom frame
5 mm
(R2808)
(R9582)
184

Advertisement

Table of Contents
loading

Table of Contents