SiBE04-808_B
Step
2. Remove the indoor heat
exchanger.
1
Unfasten the hook of
the piping fixture at the
back of the indoor unit
and pull out the pipe.
Widen the auxiliary pipe
2
by about 10-20
degrees.
3
Remove the 2 screws
on the left side.
Unfasten the lower
4
hook on the right side
with a flat screwdriver.
Removal Procedure
Procedure
Piping
fixture
Lower hook
Preparation
Remove the indoor unit from
the installation plate.
(R10622)
When dismounting or
mounting the indoor heat
exchanger, be sure to wear
gloves or wrap it with cloth
before proceeding. (You may
be injured by the fins.)
Unbending angle:
10-20 deg.
(R10543)
(R10546)
(R10326)
Indoor Unit