Daikin G-Series Service Manual page 19

Inverter pair wall mounted type
Hide thumbs Also See for G-Series:
Table of Contents

Advertisement

SiBE04-808_B
Indoor Units
Models
Outdoor Units
Capacity
Rated (Min. ~ Max.)
Moisture Removal
Running Current (Rated)
Power Consumption
Rated (Min. ~ Max.)
Power Factor
COP (Rated)
Liquid
Piping
Gas
Connections
Drain
Heat Insulation
Max. Interunit Piping Length
Max. Interunit Height Difference
Chargeless
Amount of Additional Charge of
Refrigerant
Indoor Units
Front Panel Color
m³/min
Airflow Rate
(cfm)
Type
Fan
Motor Output
Speed
Air Direction Control
Air Filter
Running Current (Rated)
Power Consumption (Rated)
Power Factor
Temperature Control
Dimensions (H × W × D)
Packaged Dimensions (H × W × D)
Weight
Gross Weight
Operation
H / M / L / SL
Sound
Sound Power
Outdoor Units
Casing Color
Type
Compressor
Model
Motor Output
Type
Refrigerant
Oil
Charge
Type
Refrigerant
Charge
m³/min
Airflow Rate
(cfm)
Type
Fan
Motor Output
Running Current (Rated)
Power Consumption (Rated)
Power Factor
Starting Current
Dimensions (H × W × D)
Packaged Dimensions (H × W × D)
Weight
Gross Weight
Operation
H / SL
Sound
Sound Power H
Drawing No.
Note:
Specifications
kW
Btu/h
14,300 (5,800 ~ 17,100)
kcal/h
3,610 (1,460 ~ 4,300)
L/h
A
W
1,220 (440 ~ 2,230)
%
89.4 - 89.9 - 90.8
W/W
3.44 (3.86 ~ 2.24)
mm
mm
mm
Both Liquid and Gas Pipes
m
m
m
g/m
H
M
L
SL
W
Steps
5 Steps, Quiet, Auto
Right, Left, Horizontal, Downward
Removable / Washable / Mildew Proof
A
0.11 - 0.11 - 0.10
W
%
99.2 - 94.9 - 100.0
Microcomputer Control
mm
mm
kg
kg
dBA
dBA
Hermetically Sealed Swing Type
W
L
kg
HH
SL
W
A
6.04 - 5.78 - 5.54
W
1,196 - 1,196 - 1,196
%
90.0 - 90.0 - 90.0
A
mm
mm
kg
kg
dBA
dBA
The data are based on the conditions shown in the table below.
Cooling
Indoor ; 27°CDB / 19°CWB
Outdoor ; 35°CDB / 24°CWB
FTXS42G2V1B
RKS42G2V1B
4.2 (1.7 ~ 5.0)
2.3
6.2 - 5.9 - 5.6
φ
6.4
φ
9.5
φ
18.0
20
15
10
20
FTXS42G2V1B
White
9.1 (321)
7.7 (273)
6.3 (221)
5.4 (190)
Cross Flow Fan
23
24 - 24 - 24
295 × 800 × 215
274 × 870 × 366
10
13
42 / 38 / 33 / 30
58
RKS42G2V1B
Ivory White
2YC36BXD
1,100
FVC50K
0.65
R-410A
1.30
37.3 (1,317)
30.6 (1,079)
Propeller
50
6.2
550 × 765 × 285
612 × 906 × 364
39
45
48 / 44
63
3D059730
Piping Length
5 m
Specifications
50 Hz, 220 - 230 - 240 V
FTXS50G2V1B
RKS50G2V1B
5.0 (1.7 ~ 5.3)
17,100 (5,800 ~ 18,100)
4,300 (1,460 ~ 4,560)
2.8
7.1 - 6.7 - 6.5
1,520 (440 ~ 1,810)
97.3 - 98.6 - 97.4
3.29 (3.86 ~ 2.93)
φ
6.4
φ
12.7
φ
18.0
Both Liquid and Gas Pipes
30
20
10
20
FTXS50G2V1B
White
10.2 (360)
8.6 (305)
7.0 (246)
6.0 (212)
Cross Flow Fan
23
5 Steps, Quiet, Auto
Right, Left, Horizontal, Downward
Removable / Washable / Mildew Proof
0.12 - 0.12 - 0.11
26 - 26 - 26
98.5 - 94.2 - 98.5
Microcomputer Control
295 × 800 × 215
274 × 870 × 366
10
13
43 / 39 / 34 / 31
59
RKS50G2V1B
Ivory White
Hermetically Sealed Swing Type
2YC36BXD
1,100
FVC50K
0.65
R-410A
1.70
50.9 (1,797)
48.9 (1,727)
Propeller
53
6.93 - 6.63 - 6.35
1,494 - 1,494 - 1,494
98.0 - 98.0 - 98.0
7.1
735 × 825 × 300
797 × 960 × 390
47
52
48 / 44
62
3D059731
Conversion Formulae
kcal/h = kW × 860
Btu/h = kW × 3412
cfm = m³/min × 35.3
8

Advertisement

Table of Contents
loading