Daikin G-Series Service Manual page 177

Inverter pair wall mounted type
Hide thumbs Also See for G-Series:
Table of Contents

Advertisement

SiBE04-808_B
Step
4. Remove the vertical blade
ASSY.
1
Detach the pivot from
the interlock shaft for
vertical blades with a
flat screwdriver.
2
Remove the interlock
rod.
Unfasten the hooks at
3
the upper 3 positions by
pressing them with a
flat screwdriver.
Remove the vertical
4
blade ASSY.
Removal Procedure
Procedure
Vertical blade ASSY
Interlock rod
Pivot
Interlock
shaft
(R12270)
(R10302)
(R10303)
Hook
(R12269)
Indoor Unit
Points
A vertical blade ASSY has 5
fins. It is impossible to
replace only one fin.
The vertical blade ASSY is
not marked for difference
between right and left.
166

Advertisement

Table of Contents
loading

Table of Contents