SiBE04-808_B
Check Method 2
1. Press the 3 buttons (TEMP ▲ , TEMP ▼ , MODE) at the same time.
2. Press the TEMP ▲ or ▼ button and change the figure until you hear the sound of "beep" or "pi
3. Diagnose by the sound.
4. Press the MODE button.
Service Diagnosis
The figure of the ten's place blinks.
pi".
"pi" : The figure of the ten's place does not accord with the error code.
"pi pi" : The figure of the ten's place accords with the error code but the one's not.
"beep" : The both figures of the ten's and one's place accord with the error code.
(Error codes and description
The figure of the one's place blinks.
(R8381)
(R8382)
(R8383)
Refer to page 103.)
(R8384)
(R8385)
Service Check Function
98