Daikin G-Series Service Manual page 225

Inverter pair wall mounted type
Hide thumbs Also See for G-Series:
Table of Contents

Advertisement

SiBE04-808_B
Step
3. Remove the fan motor.
Remove the washer-
1
fitted nut of the outdoor
fan.
Remove the outdoor
2
fan.
3
Release the outdoor
temperature thermistor.
Removal Procedure
Outdoor Unit - RK(X)S20-35G2V1B9, ARXS20-35G3V1B
Procedure
Outdoor fan
D-cut
Outdoor temperature
thermistor
The screw has reverse
winding.
Nut size: M6
(R11827)
When reassembling, align
mark of the outdoor fan
with D-cut section of the
motor shaft.
(R11828)
(R11829)
Points
10 mm
(R12236)
214