Appendix E - System Events - Graco HFR Setup And Operation

For nvh foam - cart hydraulic, plural-component, fixed-ratio proportioner. for dispensing nvh foam.
Hide thumbs Also See for HFR:
Table of Contents

Advertisement

Appendix E - System
Events
Event Code and
String
Triggers
EAA0-R: Prepoly
While in night mode, the prepoly
Refresh Started
refresh started.
EBA0-R: Prepoly
While in night mode, the prepoly
Refresh Complete
refresh completed successfully.
EL00-R: System
The System was powered on.
Powered On
EM00-R: System
The System was powered off.
Powered Off
EB00-R: Stop Button
The Red stop button was pressed on
Pressed
the Advanced Display Module.
ECH0-R: Learn Mode
A learn mode calibration was success-
Executed
fully completed.
ENN0-R: Automatic
The system was successfully charac-
Cal. Performed
terized with the Automatic calibration.
ECA1-R: Red Mate-
The Red materials specific gravity was
rial SG Modified
modified.
ECB2-R: Blue Mate-
The Blue materials specific gravity was
rial SG Modified
modified.
ENC1-R: Cal. Point 1
A value for the first point in the three
Weight Entered
point calibration was entered.
ENC2-R: Cal. Point 2
A value for the second point in the
Weight Entered
three point calibration was entered.
ENC4-R: Cal. Point 1
The running average for point one of
Weight Erased
the three point calibration was erased.
ENC5-R: Cal. Point 2
The running average for point two of
Weight Erased
the three point calibration was erased.
END0-R: Ratio Check
A ratio check shot was dispensed from
Dispense
the ratio check calibration screen.
EA00-R: Disp.
A dispense has occurred of the given
Occurred (Shot #)
shot number.
EH00-R: Gel Timer
The gel timer expired and the system
Dispense
automatically took the gel shot.
ER01-R: Shot Count
A counter from the shot counters main-
Reset
tenance page was erased
ER02-R: Seq. Posi-
A counter from the sequence counters
tion Count Reset
maintenance page was erased
ERA1-R: Red Mate-
The resettable totalizer for the Red
rial Volume Reset
material volume was reset to zero.
ERB1-R: Blue Mate-
The resettable totalizer for the Blue
rial Volume Reset
material volume was reset to zero.
ERA2-R: Red Mate-
The resettable totalizer for the Red
rial Weight Reset
material weight was reset to zero.
ERB2-R: Blue Mate-
The resettable totalizer for the Blue
rial Weight Reset
material weight was reset to zero.
ERA3-R: Red Cycle
The resettable cycle counter for the
Count Reset
Red pump was reset to zero.
ERB3-R: Blue Cycle
The resettable cycle counter for the
Count Reset
Blue pump was reset to zero.
3A2797R
Event Code and
String
Triggers
EQU1-R: Settings
The system settings were successfully
Downloaded
transferred from the ADM to a USB
drive.
REQU-R: Settings
The system settings file was success-
Uploaded
fully transferred from the USB drive to
the ADM.
EQU3-R: Language
The custom language file was suc-
Downloaded
cessfully transferred from the ADM to
a USB drive.
EQU4-R: Language
The custom language file was suc-
Uploaded
cessfully transferred from the USB
drive to the ADM.
EQU5-R: Logs Down-
The Error/Event and Shot data logs
loaded
were successfully transferred from the
ADM to a USB drive.
EA0-R: Night Mode
While in night mode the system has
Recirc On
automatically entered a low circulation
mode and attempted to turn on all
enabled conditioning zones.
EBR0-R: Night Mode
While in night mode the system has
Recirc Off
automatically stopped the low circula-
tion mode and turned off all condition-
ing zones.
EWA0-R: Prepoly
While in night mode, the prepoly
Refresh Cancelled
refresh was cancelled

Appendix E - System Events

89

Advertisement

Table of Contents
loading

Table of Contents