Startup - Graco HFR Setup And Operation

For nvh foam - cart hydraulic, plural-component, fixed-ratio proportioner. for dispensing nvh foam.
Hide thumbs Also See for HFR:
Table of Contents

Advertisement

Startup

To reduce the risk of personal injury, do not operate
HFR without all covers and shrouds in place.
1. Check that all machine connections are setup. See
Setup procedure, page 28.
2. Check level and condition of ISO lube daily, see
IsoGuard Select
3. Verify both PRESSURE RELIEF/DISPENSE valves
(SA, SB) are set to DISPENSE
SA
4. If dispense valve has a trigger safety lock, engage
the trigger safety lock.
LOCKED
5. Open system fluid inlet valves and ball valves found
on the material tanks. As applicable, ball valves on
the material tanks include material supply, applica-
tor return, and pressure relief. Check for leaks.
3A2797R
System on page 48.
.
ti10442a1
6. Press
green.
7. Navigate to Home Standby screen and press
to initiate auto startup.
8. Check that heat zones are on and temperatures are
on target. Check fluid pressure display. Refer to
Status Screen on page 73 for more details.
SB
9. If dispense valve has a trigger safety lock, disen-
gage the trigger safety lock.
ti9877a1
i.
Equipment is ready to dispense.
to enable system. LED should be solid
ti10441a1
UNLOCKED