Technical Data

Motor Control Module Technical Data

Motor Control Module
Input Specifications:
Input Line Voltage
Input Line Phasing
Input Line Frequency
Input Current per Phase
Maximum Branch Circuit Protection Rating
Short Circuit Current Rating
Output Specifications:
Output Line Voltage
Output Line Phasing
Output Current
Output Overload
DC Power Supply
Enclosure
Max Ambient Temperature
Overtemperature protection is provided to protect from motor overload.
Current limit, set via the software, is provided as a secondary protection from motor overload.
All installations and wiring must comply with NEC and local electrical codes.
98
US
0-264 Vac, line-to-line
Single or Three Phase
50/60 Hz
25A (three-phase), 50A (single-phase)
30A (three-phase), 63A (single-phase)
5 kA
0-264 Vac
Three Phase
0-30A
200% for 0.2 seconds
24 Vdc, Class 2, Graco-provided power supply
Type 1
50°C (122°F)
Metric
3A2797R