Graco Pro/Delta Spray 240367 Instructions-Parts List Manual

Acetal husky 307, stand mount, pro/ delta spray packages 100 psi (0.7 mpa, 7 bar) maximum fluid working pressure 100 psi (0.7 mpa, 7 bar) maximum air inlet pressure

Advertisement

Quick Links

INSTRUCTIONS–PARTS LIST
This manual contains important
warnings and information.
READ AND KEEP FOR REFERENCE.
INSTRUCTIONS
ACETAL HUSKYt 307, STAND MOUNT
PROt/ Delta Sprayt Packages
Metal fluid fittings and hose couplings are stainless steel.
100 psi (0.7 MPa, 7 bar) Maximum Fluid Working Pressure
100 psi (0.7 MPa, 7 bar) Maximum Air Inlet Pressure
Packages with Fluid Pressure Regulators
Model No. 240367
with hoses and Delta Spray air spray gun
Model No. 240368
with hoses and Delta Spray HVLP gun
Model No. 240369
with hoses and PRO 3500sc electrostatic gun
Model No. 240370
with hoses and PRO 4500sc electrostatic gun
Model No. 240371
no hoses or gun
Packages with Surge Tanks
Model No. 240379
with hoses and Delta Spray air spray gun
Model No. 240380
with hoses and Delta Spray HVLP gun
Model No. 240381
no hoses or gun
This gun and hose for Delta Spray Air Spray
packages and Delta Spray HVLP packages
GRACO INC. P.O. BOX 1441 MINNEAPOLIS, MN 55440–1441
ECOPYRIGHT 1998, GRACO INC.
Graco Inc. is registered to I.S. EN ISO 9001
First choice when
quality counts. t
This manual contains
changes not included
throughout the contents.
Please see the second
page of this book (page 1A)
for a description of the
revisions and additions.
This gun and hose for PRO 3500sc
Electrostatic packages
308846
Rev. D
8115A

Advertisement

Table of Contents
loading

Summary of Contents for Graco Pro/Delta Spray 240367

  • Page 1 INSTRUCTIONS–PARTS LIST This manual contains important warnings and information. READ AND KEEP FOR REFERENCE. INSTRUCTIONS ACETAL HUSKYt 307, STAND MOUNT PROt/ Delta Sprayt Packages Metal fluid fittings and hose couplings are stainless steel. 100 psi (0.7 MPa, 7 bar) Maximum Fluid Working Pressure 100 psi (0.7 MPa, 7 bar) Maximum Air Inlet Pressure Packages with Fluid Pressure Regulators Model No.
  • Page 2 Instruction Manual – Parts List Changes This page contains a summary of changes or additions that do not appear in the contents of the manual. Improve pressure control instructions (Graco ref. V6557). Change 30psi HVLP fluid regulator and gauge to 60psi (Graco ref. V6808). 308846...
  • Page 3 Notes 308846...
  • Page 4: Table Of Contents

    Table of Contents Warnings ....... . . Setup ........Operation .
  • Page 5 EQUIPMENT MISUSE HAZARD Equipment misuse can cause the equipment to rupture, malfunction, or start unexpectedly and result INSTRUCTIONS in a serious injury. D This equipment is for professional use only. D Read all the instruction manuals, tags, and labels before operating the equipment. D Use the equipment only for its intended purpose.
  • Page 6: Setup

    CAUTION This equipment is compatible with most water-based materials. See the wetted parts in the Technical Data section and your fluid and solvent manufacturer’s compatibility information. Do not use acid catalyzed materials; they are incom- patible with the acetal used in this pump. WARNING TOXIC FLUID HAZARD Hazardous fluid or toxic fumes can...
  • Page 7 Hose Connections This package is shipped with the hoses connected. Before you disconnect any hoses, make a note of the proper connections. Flush Pump Before First Use The pump was tested in water. If the test solution could contaminate the fluid you are pumping, flush the pump thoroughly with a compatible solvent.
  • Page 8: Operation

    Using the Gun See the gun instruction manual for gun operation, care, flushing, cleaning, and technical data. Read the entire gun manual before operating the sprayer. Pressure Relief Procedure See Fig. 1 WARNING The system remains pressurized until pressure is manually relieved.
  • Page 9 Priming the System See Fig. 1 1. Close the gun air regulator (F). 2. If your system has a fluid pressure regulator (G), close it. 3. Open the recirculating valve (J). 4. Open the bleed-type master air valve (K). 5. Slowly set the pump air regulator (E) pressure to 20 to 30 psi (140 to 210 kPa, 1.4 to 2.1 bar).
  • Page 10 Using the Recirculation Feature See Fig. 1 The recirculation tube drains unused fluid back into the fluid container, ensuring an even flow at the gun. Recirculation also provides gentle fluid agitation. To recirculate fluid, open the recirculation valve (J) while you are spraying.
  • Page 11: Maintenance

    See the separate component instruction manuals for individual component maintenance procedures. Access to some system components requires that you remove the shields. The following steps are for shield removal. Shield replacement is the reverse of these steps, so make sure you take notes on the proper hose connections.
  • Page 12: Parts List And Parts Drawing 240367 To 240371

    Stand-Mount Packages with Fluid Pressure Regulators Model No. 240367, Delta Spray air spray package Model No. 240368, Delta Spray HVLP package Model No. 240369, PRO 3500sc electrostatic package Model No. 240370, PRO 4500sc electrostatic package Model No. 240371, no hoses or gun Ref.
  • Page 13: Parts Drawing

    Stand-Mount Packages with Fluid Pressure Regulators Model No. 240367, Delta Spray air spray package Model No. 240368, Delta Spray HVLP package Model No. 240369, PRO 3500sc electrostatic package Model No. 240370, PRO 4500sc electrostatic package Model No. 240371, no hoses or gun Grounding Detail Parts Drawing Note: For PRO packages only, terminal...
  • Page 14: 240379 And 240381

    Stand-Mount Packages with Surge Tanks Model No. 240379, Delta Spray air spray package Model No. 240380, Delta Spray HVLP package Model No. 240381, no hoses or gun Ref. Part No. Description 240210 SHIELD ASSY, front Contains 1a to 1h, shown in Fig. 2 on page 9 054139 TUBE, suction...
  • Page 15 Stand-Mount Packages with Surge Tanks Model No. 240379, Delta Spray air spray package Model No. 240380, Delta Spray HVLP package Model No. 240381, no hoses or gun Grounding Detail Parts Drawing 8048A 308846...
  • Page 16: Fluid Filter Kit 240440

    Accessory Fluid Filter Kit Fluid Filter Kit 240440 Ref. Part No. Description 114361 FILTER, fluid 113322 CONNECTOR, male 054188 TUBE; PTFE;R3/8” O.D. 113534 ELBOW, male x female 111917 NIPPLE; Nylon The Fluid Filter Kit, listed above, can be installed to filter fluid drawn by the suction tube after it comes out of the pump.
  • Page 17: Suction Tube Kit 240465

    Accessory Suction Tube Kit Suction Tube Kit 240465 Ref. Part No. Description 232692 KIT ASSEMBLY, suction tube 193411 NIPPLE 193459 TUBE, recirculation 103473 TIE, wire The Suction Kit, listed above, can be installed for drawing fluid from a container that is not directly under the unit.
  • Page 18: Technical Data

    Category Maximum fluid working pressure Maximum incoming air pressure Maximum operating temperature Pump Fluid pressure regulator Air pressure regulators Wetted parts: fluid hoses for Delta guns Wetted parts: fluid hoses for PRO guns Wetted parts: other fluid hoses and tubing Wetted parts: fluid fittings Weight (without hoses or gun): packages with fluid pressure regulator...
  • Page 19: Dimensions

    Dimensions 34.0 in. (864 mm) 17.5 in. 16.5 in. (445 mm) (419 mm) 8171A 308846...
  • Page 20 Notes 308846...
  • Page 21 Notes 308846...
  • Page 22: Graco Standard Warranty

    Manual Change Summary This manual went from Rev. A to Rev. B to make the following changes: D Model No. 240371 (regulated packages with no hoses or gun) and Model No. 240381 (surge tank packages with no hoses or gun) are added. See the front cover and the Parts Lists on pages 10 and 12. D Part No.

Table of Contents