E-Rds; Report - Canon imageRUNNER 2525 Series Service Manual

Hide thumbs Also See for imageRUNNER 2525 Series:
Table of Contents

Advertisement

There is no function to display the license registration numbers in the main unit.
Therefore, when there is a possibility to restore the license after erasing it, make sure that a user has written down the license
registration number.
When a license option is displayed in Procedure (4), 001 1 is displayed.
The last "1" shows that the license is validated by license authentication.
After the license is erased, the last number is changed to "2".
When the option is standard, the last number shows "3" which means disable for license transfer.
Details about the last number:
1. The function is validated.
2. The function is invalidated, or a license is transferred.
3. The function is invalidated, or the license does not exist.

#E-RDS

■ Configuration
Settings related to e-RDS are described below.
Item
Default
E-RDS SWITCH 0
RGW- AD-
URL of UGW Character string length:
DRESS
RGW-PORT
443
CNT-DATE
CNT-INTV
24
COM-TEST
COM-LOG
SCALLCMP

#REPORT

■ Configuration
The table below lists the kinds of reports that are supported.
Setting range
0 or 1
e-RDS OFF/ON setting (0:OFF / 1:ON)When used (ON), the counter infor-
mation and error information are sent to UGW.Default: 0 (OFF)
URL of UGWDefault: URL of actual UGWCharacter string length: 129 bytes
129byte (including
(including NULL, one-byte codes only)
NULL, one-byte codes
only)
1-65535
Port No. of UGW Default: 443Setting range: 1 to 65535
Setting of the date of sending the counter information to the server (Valid
after input of license).
Set the start date of the schedule to send the counter information to the
server using a third party expansion function of E-RDS.
Refer to the user mode date setting.
(12 digits: YYYYMMDDHHMM)
YYYY: Year MM: Month
DD: Day
HH: Hour
MM: Minute
1-168 (on a weekly ba-
Setting of the interval of sending the counter information to the server (Valid
sis)
after input of license).
Set the interval of sending the counter information to the server using a third
party expansion function of E-RDS.
Execution of communication test An attempt is made to connect to UGW,
judges whether connection is successful, and displays "COM- TEST OK" or
"COMTEST NG" as the judgment result.
Details of communication test result. The log of errors in communication with
UGW is displayed. The error information includes the error occurrence time,
error code, and details of the error.Maximum log count: 5Error information
length: Max. 128 characters (excluding NULL)
Repair completion process (call button function) Used when the service
personnel has completed the requested repair.
Description
284
8. Service Mode

Advertisement

Table of Contents
loading

This manual is also suitable for:

Imagerunner 2520 seriesImagerunner 2530 series