■ Standby temperature control
Fixing
temperature
● Flying start temperature control
Purpose:
• To reduce the print time (FPOT) of the 1st sheet
Starting conditions:
• When opening the copyboard cover or ADF, and also the detection temperature of the main thermistor is less than 100 deg
C.
• When the original sheet is set on the ADF tray, and also the detection temperature of the main thermistor is less than 100
deg C.
• When the main power switch is turned ON or the machine condition is shift from the sleep mode to standby, and also the
detection temperature of the main thermistor is less than 155 deg C.
Control description:
• The target control temperature is set to 165 deg C and the fixing motor starts to rotate with a half speed. The control continues
for maximum 10 seconds.
INTR
STBY
Flying start
control
temperature
Max. 10 sec
Command for
flying start
PRNT