Siemens SINAMICS S120 Manual page 320

Sinamics family modular motion control drives
Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

Service and Maintenance
10.2 Service and maintenance for components, Blocksize format
Figure 10-4
Replacing the fan for a Power Module PM340, frame size FSF
5. Release the screws and remove the cover.
6. Withdraw the two connectors shown and lift-out the fan.
7. Insert the new fan, locate both connectors, close the cover and tighten the screws
(tightening torque, 3.0 Nm).
320
Manual, (GH6), 07/2007 Edition, 6SL3097-2AL00-0BP2