X520 sensor system

Table 7-9
Sensor interface X520
Pin
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
240
Signal name
Reserved, do not use
Reserved, do not use
S2
S4
Ground
S1
S3
Ground
R1
Reserved, do not use
R2
Reserved, do not use
+Temp
Reserved, do not use
Reserved, do not use
Reserved, do not use
Reserved, do not use
Reserved, do not use
Reserved, do not use
Reserved, do not use
Reserved, do not use
Reserved, do not use
Reserved, do not use
Ground
-Temp
Technical data
Resolver signal A (sin+)
Inverse resolver signal A (sin-)
Ground (for internal shield)
Resolver signal B (cos+)
Inverse resolver signal B (cos-)
Ground (for internal shield)
Resolver excitation positive
Resolver excitation negative
Motor temperature measurement KTY84-1C130 (KTY+)
Temperature sensor connection KTY84-1C130 / PTC
Ground (for internal shield)
Motor temperature measurement KTY84-1C130 (KTY-)
Temperature sensor connection KTY84-1C130 / PTC