CONTROL PANEL
INPUT LOOP LIMITS:
• 128 mA MAX. LIMIT CURRENT TO 64mA ON ANY
INDIVIDUAL WIRE RUN.
• NO MORE THAN 64 DEVICES MAY BE USED.
NO INDIVIDUAL WIRE RUN CAN EXCEED:
GAUGE
LENGTH
#22
650 FT
#20
950 FT
#18
1500 FT
#16
2400 FT
• TOTAL LENGTH OF ALL WIRE RUNS COMBINED CANNOT
EXCEED 4000FT. (2000FT. IF USING SHIELDED WIRE)

Figure 3-17: Polling Loop Connections Using One 4297 Extender Module

• DO NOT CONNECT 4297 MODULES IN
SERIES (i.e., DO NOT CONNECT ONE
MODULE'S EXTENSION LOOP TO
ANOTHER MODULE'S INPUT LOOP.)
CONTROL PANEL
COMBINED INPUT AND EXTENSION LOOP LIMITS:
• NO MORE THAN 119 DEVICES COMBINED ON THE INPUT LOOP AND EXTENSION
LOOP #1. NO MORE THAN 119 DEVICES COMBINED ON THE INPUT LOOP AND
EXTENSION LOOP #2.
• TOTAL LENGTH OF ALL WIRE RUNS ON THE INPUT LOOP AND EXTENSION LOOP #1
COMBINED CANNOT EXCEED 6400 FT. (3200 FT. IF USING UNSHIELDED WIRE IN
CONDUIT, OR SHIELDED WIRE). TOTAL LENGTH OF ALL WIRE RUNS ON THE INPUT
LOOP AND EXTENSION LOOP #2 COMBINED CANNOT EXCEED 6400 FT. (3200 FT. IF
USING UNSHIELDED WIRE IN CONDUIT, OR SHIELDED WIRE).

Figure 3-18: Polling Loop Connections Using Multiple Extender Modules

NOTE: The input loop limits stated in Figure 3-17 apply to Figure 3-18 as well.

Wireless Zone Expansion

The 5881ENHC RF Receiver and the 5869 Holdup
U L
Switch Transmitter are listed for UL Commercial
Burglary applications. All other RF receivers and
transmitters are not listed for UL Commercial
Burglary applications.
The following table lists the receivers that may be used
and the number of zones they support.
5800 Series Receivers
Receiver
5881L
5881M
5881H
WWW.DIYALARMFORUM.COM
INPUT POLLING LOOP
RPM
RPM
INPUT POLLING LOOP
Zones
up to 8
up to 16
up to 250
WWW.DIYALARMFORUM.COM
Section 3 - Installing the Control
EXTENSION POLLING LOOP
4297
EXTENSION POLLING LOOP LIMITS = SAME AS INPUT LOOP
COMBINED INPUT AND EXTENSION LOOP LIMITS:
• NO MORE THAN119 DEVICES COMBINED.
• TOTAL LENGTH OF ALL WIRE RUNS ON BOTH
LOOPS COMBINED CANNOT EXCEED 6400 FT.
3200 FT. IF USING UNSHIELDED WIRE IN
CONDUIT, OR IF USING SHIELDED WIRE
EXTENSION POLLING LOOP #1
4297
EXTENSION POLLING LOOP #2
4297
In Canada, 5800 systems must use 5882 Series
receivers: 5882L/5882H. Information to the 5881
Receivers applies as well to the 5882 Receivers.
Both receivers use the same transmitters.
RF System Operation and Supervision
The 5800 RF system operation has the following
characteristics:
The receiver responds to a frequency of 345MHz.
The receiver has a nominal range of 200 feet.
Supervised transmitters send a supervisory signal
every 70-90 minutes.
RPM
RPM
RPM
RPM
TO
OTHER
RPMS
3-13