Dense Wavelength Division Multiplexing Commands on the Cisco ASR 9000 Series Router

g709 otu threshold

To configure thresholds for selected Optical Channel Transport Unit (OTU) bit error rate (BER) alarms, use
the g709 otu threshold command in DWDM configuration mode. To return to the default state, use the no
form of this command.
g709 otu threshold {sd-ber| sf-ber} bit-error-rate
no g709 otu threshold {sd-ber| sf-ber} bit-error-rate
Syntax Description
sd-ber bit-error-rate
sf-ber bit-error-rate
Command Default
The defalut bit error rate for sd-ber is 6.
The default bit error rate for sf-ber is 3.
Command Modes
DWDM configuration
Command History
Release
Release 3.9.0
Usage Guidelines
To use this command, you must be in a user group associated with a task group that includes appropriate task
IDs. If the user group assignment is preventing you from using a command, contact your AAA administrator
for assistance.
Task ID
Task ID
dwdm
Examples
This example shows how to set the signal fail BER rate to be 5:
RP/0/RSP0/CPU0:router(config)# controller dwdm 0/0/0/0
Signal degradation bit error rate (BER) in the range 1 to 9, where bit-error-rate
specifies a negative exponent of base 10 (10–bit-error-rate). The default is 6
(10–6).
Signal failure BER above threshold in the range 1 to 9, where bit-error-rate
specifies a negative exponent of base 10 (10–bit-error-rate). The default is 3
(10–3).