Waste Toner Overflow Sensor - Ricoh MD-P2 Field Service Manual

Table of Contents

Advertisement

Image Transfer
4
5. Waste toner sensor base [B]
6. Remove the mylar at the bottom of the waste toner bottle set sensor.
7. Waste toner bottle set sensor [C] (hooks,
x 1)
• When reinstalling the waste toner bottle set sensor, connect it to the white connector of the harness.

Waste Toner Overflow Sensor

1. Remove all AIO cartridges. (
p.36)
2. Image transfer belt unit (
p.41)
3. EGB (
p.79)
4. Waste toner sensor base (
p.46 "Waste Toner Bottle Set Sensor")
47