[Save Tone Control Value]
Stores the print gamma adjusted with the "Gamma Adj." menu item as the current setting.
1105
Before the machine stores the new "current setting", it moves the data currently stored as
the "current setting" to the "previous setting" memory storage location.
1105 1 Save Tone Control Value
[Toner Limit]
1106
Adjusts the maximum toner amount for image development.
1106 1 Toner Limit Value

Engine SP

SP1-XXX (Feed)
[Lead Edge Reg.] Leading Edge Registration
1001
(Tray or By-pass, Paper Type, Process Speed)
Process Speed: LowSpd: Low Speed, HlfSpd: Half speed, NorSpd: Normal speed
• Adjusts the leading edge registration. This SP changes the registration clutch
operation timing for each mode.
• A +ve value sets the registration start timing earlier.
• A –ve value sets the registration start timing later. The value of the normal paper in
RS is the standard value. The values of papers other than normal are added to the
value of the normal paper in RS.
002 T1:NorSpd 0.3mm
003 T1:HlfSpd 0.3mm
006 T2:NorSpd 0.3mm
007 T2:HlfSpd 0.3mm
014 ByPas:NorSpd 0.3mm
015 ByPas:HlfSpd 0.3mm
*CTL
[100 to 400 / 260 / 1 %/step ]
*EGB
[-9.0 to 9.0 / 0 / 0.3 mm/step]
*EGB
[-9.0 to 9.0 / 0 / 0.3 mm/step]
*EGB
[-9.0 to 9.0 / 0 / 0.3 mm/step]
*EGB
[-9.0 to 9.0 / 0 / 0.3 mm/step]
*EGB
[-9.0 to 9.0 / 0 / 0.3 mm/step]
*EGB
[-9.0 to 9.0 / 0 / 0.3 mm/step]