6. Troubleshooting
Error Messages
Overview
The error messages will be displayed on the LCD of the operation panel if the machine has a problem.
These can be recovered by a customer.
Error Messages List
Cover Open
The front or top cover is open.
000
1. Close the front or top cover.
2. Replace the interlock switches or actuator mechanism.
010
AIO Set Error (Black)
011
AIO Set Error (Magenta)
012
AIO Set Error (Cyan)
013
AIO Set Error (Yellow)
• Black AIO not set
• Defective connection of the ID chip terminal on the black AIO
1. Install the AIO (black, magenta, cyan or yellow).
1. Reinstall or replace the AIO (black, magenta, cyan or yellow).
ITB (Image Transfer Belt) Unit Set Error
• ITB unit not set
015
• The machine does not detect any signal from the TM sensors while the ITB contact motor
is initializing.
Install the ITB unit.
6
189