Toshiba PORTEGE R200 Maintenance Manual page 52

Personal computer
Hide thumbs Also See for PORTEGE R200:
Table of Contents

Advertisement

2 Troubleshooting
2-12
Downloaded from
www.Manualslib.com
E3V output
Error code
Meaning
60h
E3V voltage is over 3.96V when the computer is powered on/off.
61h
E3V voltage is under 2.81V when the computer is powered on.
62h
E3V voltage is under 2.81V when the computer is booting up.
63h
E3V voltage is over 2.81V while the computer is powered off.
64h
E3V voltage is under 2.81V while the computer is suspended.
1R5-E1V output
Error code
Meaning
70h
1R5-E1V voltage is over 1.80V when the computer is powered on/off.
71h
1R5-E1V voltage is under 1.275V when the computer is powered on.
72h
1R5-E1V voltage is under 1.275V when the computer is booting up.
73h
1R5-E1V voltage is over 1.275V when the computer is powered off.
1R8-B1V output
Error code
Meaning
80h
1R8-B1V voltage is over 2.16V when the computer is powered on/off.
81h
1R8-B1V voltage is under 1.53V when the computer is powered on.
82h
1R8-B1V voltage is under 1.53V when the computer is booting up.
83h
1R8-B1V voltage is over 1.53V when the computer is powered off.
84h
1R8-B1V voltage is under 1.53V when the computer is suspended.
PPV output
Error code
Meaning
90h
PPV voltage is over 1.20V when the computer is powered on/off.
91h
PPV voltage is under 0.56V when the computer is powered on.
92h
PPV voltage is under 0.56V when the computer is booting up.
93h
PPV voltage is over 0.56V when the computer is powered off.
[CONFIDENTIAL]
manuals search engine
2.3 Power Supply Troubleshooting
PORTEGE R200 Maintenance Manual (960-519)

Advertisement

Table of Contents
loading

Table of Contents