3.14 Real Timer Test
Subtest 03
CAUTION: When this subtest is executed, the current date and time are erased.
PORTEGE R200 Maintenance Manual (960-519)
Downloaded from
www.Manualslib.com
Real time carry
This subtest checks the real time clock increments, making sure the date and
time are displayed in the following format:
Current date : 12-31-1999
Current time : 23:59:58
The real time increments are automatically executed and the following is
displayed:
Current date :
Current time :
PRESS [Enter] KEY TO EXIT TEST
To exit the test, press Enter.