Detaching And Refitting The Scanner Wires - Kyocera KM-2560 Service Manual

Hide thumbs Also See for KM-2560:
Table of Contents

Advertisement

(3) Detaching and refitting the scanner wires

Take the following procedure when the scanner wires are broken or to be replaced.
(3-1) Detaching the scanner wires
Procedure
1. Remove the scanner unit (see page 1-5-19).
2. Remove the exposure lamp (see page 1-5-
15).
3. Remove the screw and remove the slit
holder plate.
4. Remove the slit glass.
5. Remove each screw and remove front and
rear wire holder plates.
6. Remove the mirror 1 frame from the scanner
unit.
Screw
Slit holder
plate
Mirror 1 frame
Screw
Front wire
holder plate
Slit glass
Scanner unit
Figure 1-5-42
Rear wire
holder plate
Figure 1-5-43
2H0/2HZ
Screw
1-5-23