Display Transceiver Interface - HP FlexFabric 7900 Series Command Reference Manual

Hide thumbs Also See for FlexFabric 7900 Series:
Table of Contents

Advertisement

Alarm thresholds:
Temp.(°C) Voltage(V)
High
75
Low
-5
Table 39 Command output
Field
transceiver diagnostic information
Temp.(°C)
Voltage(V)
Bias(mA)
RX power(dBm)
TX power(dBm)

display transceiver interface

Use display transceiver interface to display the key parameters of transceiver modules.
Syntax
display transceiver interface [ interface-type interface-number ]
Views
Any view
Predefined user roles
network-admin
network-operator
mdc-admin
mdc-operator
Parameters
interface-type interface-number: Specifies an interface by its type and number. If you do not specify
this option, the command displays the key parameters of every transceiver module.
Examples
# Display the key parameters of the transceiver module in interface FortyGigE 1/0/1.
<Sysname> display transceiver interface fortygige 1/0/1
FortyGigE1/0/1 transceiver information:
Transceiver Type
Connector Type
Wavelength(nm)
Transfer Distance(m)
Digital Diagnostic Monitoring : YES
Vendor Name
Table 40 Command output
Field
transceiver information
Bias(mA)
3.63
10.00
2.97
0.50
Description
Digital diagnosis information of the transceiver module in the interface.
Temperature in °C, accurate to 1°C.
Voltage in V, accurate to 0.01 V.
Bias current in mA, accurate to 0.01 mA.
RX power in dBm, accurate to 0.01 dBm.
TX power in dBm, accurate to 0.01 dBm.
: 40G_BASE_SR4_QSFP_PLUS
: MPO
: 850
: 100(OM3)
: HPE
Description
Transceiver information.
228
RX power(dBm)
TX power(dBm)
3.40
N/A
-13.51
N/A

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents