Default interface condition:
Signal type
Baud rate
Data bits
Parity
Start bits
Stop bits
■ AIS data
When radar images cannot be recorded, the output data of AIS must be recorded as an alternative.
However, JCY-1800/1850 can also record both all AIS data and radar images.
■ Setup by Maintenance soft ware for recording the AIS data
Only by changing the following setup, the data outputted from AIS is recordable by the same setup as
other NMEA sentences.
• Baud rate : 38400
• Header
4.2.8. Recording Control Unit NDV-1800/1850 – Digital Signal Converter (NCT-72/63)
When mounting a Digital Signal Converter, connect the serial data line to ch13 through ch16 of the
RCU. For each Digital Signal Converter, two way communications port is needed to allow the writing of
the setting information or the updating of the software version.
Connection table: Communication line for DSC
RCU
Term #
CQD-2040
TB402
[CH-13 to 16]
1/6/11/16 [RX+]
2/7/12/17 [RX-]
3/8/13/18 [TX+]
4/9/14/19 [TX-]
5/10/15/20 [GND]
Cable Cramp
Cable Specification
Default interface condition:
Signal type
Baud rate
Data bits
Parity
Start bits
Stop bits
EIA-422 / EIA-485
4800 bps / 38400bps (for AIS)
8 (d7 = 0)
None
One
One
: !
DSC
Term #
CDJ-2333
TB101 [422]
1[TX+]
NMEA OUTPUT (Positive)
2[TX-]
NMEA OUTPUT (Negative)
4[RX+]
INPUT FOR SETTING (Positive)
5[RX-]
INPUT FOR SETTING (Negative)
3[GND]
GND
Cable Cramp
SHIELD
4 (pairs) x twist pair x 0.75 mm
EIA-422/EIA-485
4800 bps
8 (d7=0)
None
1
1
71