JRC JCY-1800 Installation Manual page 120

Voyage data recorder
Hide thumbs Also See for JCY-1800:
Table of Contents

Advertisement

8. Troubleshooting
JCY-1800/1850 VDR/S-VDR Installation Guide
Symptom
ERROR CODE: "20__"
lights up.
ERROR CODE: "21__"
lights up.
ERROR CODE: "60**"
lights up.
ERROR CODE: "61**"
lights up.
ERROR CODE: "5*__"
lights up.
ERROR CODE: "10__"
lights up.
ERROR CODE: "11__"
lights up.
ERROR CODE: "30__" /
"35__" / "36__" / "37__"
/ "38__" light up.
DOC No. 7ZPJD0387C
Causes
Faulty wiring between the Recording Control
Unit and the Protective Capsule Unit
Fault in the Recording Control Unit
Fault in the Protective Capsule Unit
Fault in recording the data in the Protective
Capsule Unit
Fault in sensors
Faulty wiring between the Recording Control
Unit and the sensors
Fault in the Recording Control Unit
Fault on setting up the Main Control Board
Fault in the Audio Recording Board
Fault in the Microphone Unit
Alarm was raised due to a large noise.
Power failure
No power is supplied from the switchboard.
The fuse for the AC power source is blown.
The fan of Power Supply Unit is not working.
Fault in the Main Control Board
Check the Connection Box.
Check the LAN communication by a PING
command.
MCB: PING 192.168.110.3
Capsule: PING 192.168.110.2
In case a no response
MCB (CDJ-2304) :
Fault in a circuit board or setting data
Capsule :
Fault in a circuit board or setting data
Reboot the Recording Control Unit, and see if
the symptom persists. If so, contact us.
Exchange a broken Unit (MCB or Capsule).
The BER ERROR could occur temporarily.
The error is canceled in less than 2 days
automatically.
If the error is not canceled after 2 days,
contact us.
Fault in the Capsule
Exchange the capsule.
Check the sensor equipment shown by error
code.
Check the wiring between the Recording
Control Unit and the sensors.
Check the receiving data and setting data by
the Maintenance software.
Reboot the Recording Control Unit. See if the
symptom persists. If so, contact us.
Reboot the Recording Control Unit, and see if
the symptom persists. If so, contact us.
Check the setting data by the Maintenance
software.
Check the wiring between the Microphone
Unit and the Recording Control Unit.
Reboot the Recording Control Unit in
noise-free environment.
In case a correct wiring
Fault in a Microphone Unit
Exchange a Microphone Unit.
Check the power supply in the Recording
Control Unit.
Check the switchboard.
Check the fuse for the AC power source and,
if it is blown, replace it with a spare fuse.
Exchange two fans in the Power Supply Unit.
Reboot the Recording Control Unit, and see if
the symptom persists. If so, contact us.
Fault in the MCB (CDJ-2304)
Exchange the MCB.
110