1. Specifications
JCY-1800/1850 VDR/S-VDR Installation Guide
1.10.3.3. Power Supply Unit
(1) Function:
a) Power supply to RCU and PCU in normal operation
b) Power supply to RCU and PCU for 2 hours on blackout.
(2) Performance:
a) Input voltage range:
b) Output voltage:
c) Maximum power output:
d) Battery capacity:
e) Expectant battery age:
1.10.3.4. External Interface
a) External alarm lamp output:
1) Interface:
2) Operation:
3) Current:
b) External alarm buzzer output:
1) Interface:
2) Operation:
3) Current:
1.10.3.5. Environmental condition
(1) Operating temperature:
(2) Temperature and humidity:
(3) Vibration:
1.10.3.6. General specification
(1) Power voltage:
(2) Power consumption:
(including capsule unit & operation panel unit & microphone phantom power)
(3) Size:
(4) Mass:
(5) Color:
DOC No. 7ZPJD0387C
100 - 120VAC +/- 10% 1-phase 50/60Hz +/-5%
200 - 240VAC +/- 10% 1-phase 50/60Hz +/-5%
(Auto switching)
5VDC, 12VDC, 24VDC
140VA
24VDC 5Ah
max 4-years
(Depending on circumstance. This age is based on ambient operating
temperature: 25 deg., load 70%)
Dry (voltage free) contact closure
System down (normal-close or open)
1A or less at 24VDC / 0.5A or less at 125VAC
Dry (voltage free) contact closure
System down (normal-close or open)
1A or less at 24VDC / 0.5A or less at 125VAC
-15°C to +55°C (IEC 60945 protected type)
+40°C, 93%
2Hz to 13.2Hz ±1.0mm
13.2Hz to 100Hz 0.7G
100 - 120VAC +/- 10% 1-phase 50/60Hz (IEC 60945)
200 - 240VAC +/- 10% 1-phase 50/60Hz (IEC 60945)
90VA in UPS battery charge
50VA in normal operation
419.5(w) x 250(d) x 480(h) mm
23.0kg (NDV-1800), 21.0kg (NDV-1850)
N7 semi-gloss texture
18